{"id":2366,"date":"2026-05-13T00:25:12","date_gmt":"2026-05-13T04:25:12","guid":{"rendered":"https:\/\/askacom.com\/?post_type=product&#038;p=2366"},"modified":"2026-06-29T16:27:45","modified_gmt":"2026-06-29T20:27:45","slug":"stranded-loose-tube-armored-cable","status":"publish","type":"product","link":"https:\/\/askacom.com\/es\/shop\/fttx-products\/fiber-optic\/duct-cables\/stranded-loose-tube-armored-cable\/","title":{"rendered":"Stranded Loose Tube Armored Cable"},"content":{"rendered":"<div style=\"font-family: inherit; max-width: 980px; margin: 24px auto; color: #111827; line-height: 1.6;\">\n<div style=\"display: flex; flex-direction: column; gap: 20px;\">\n<div style=\"position: relative; overflow: hidden; background: rgba(255,255,255,0.58); border: 1px solid rgba(255,255,255,0.72); border-radius: 28px; padding: 24px 26px; box-shadow: 0 18px 45px rgba(15,23,42,0.10), inset 1px 1px 0 rgba(255,255,255,0.92), inset -1px -1px 0 rgba(15,23,42,0.06); backdrop-filter: blur(26px) saturate(170%); -webkit-backdrop-filter: blur(26px) saturate(170%);\">\n<div style=\"position: absolute; inset: 0; pointer-events: none; background: linear-gradient(145deg, rgba(255,255,255,0.72) 0%, rgba(255,255,255,0.22) 38%, rgba(229,231,235,0.18) 100%);\"><\/div>\n<div style=\"position: absolute; top: -80px; left: -90px; width: 250px; height: 190px; border-radius: 999px; background: rgba(255,255,255,0.48); filter: blur(14px); pointer-events: none;\"><\/div>\n<div style=\"position: relative;\">\n<h3 style=\"margin: 0 0 14px 0; font-size: 22px; font-weight: 600; color: #111827; border-bottom: 1px solid rgba(17,24,39,0.10); padding-bottom: 8px;\">Description<\/h3>\n<p style=\"margin: 0; color: rgba(17,24,39,0.82);\">ASKA-LTAC-* Stranded Loose Tube Armored Cable is designed for <strong style=\"font-weight: 500 !important; color: #111827;\">outdoor duct and underground fiber optic network installation where added moisture protection and mechanical strength are required<\/strong>. The cable uses colored fibers in PBT loose tubes, an FRP or steel wire central strength member, cable filling compound, water-blocking tape, APL\/PSP armored protection, and PE or anti-tracking sheath options. It supports fiber counts up to 216 cores, making it suitable for higher-capacity backbone, distribution, and duct fiber applications.<\/p>\n<\/div>\n<\/div>\n<div style=\"position: relative; overflow: hidden; background: rgba(255,255,255,0.58); border: 1px solid rgba(255,255,255,0.72); border-radius: 28px; padding: 24px 26px; box-shadow: 0 18px 45px rgba(15,23,42,0.10), inset 1px 1px 0 rgba(255,255,255,0.92), inset -1px -1px 0 rgba(15,23,42,0.06); backdrop-filter: blur(26px) saturate(170%); -webkit-backdrop-filter: blur(26px) saturate(170%);\">\n<div style=\"position: absolute; inset: 0; pointer-events: none; background: linear-gradient(145deg, rgba(255,255,255,0.72) 0%, rgba(255,255,255,0.22) 38%, rgba(229,231,235,0.18) 100%);\"><\/div>\n<div style=\"position: absolute; top: -80px; left: -90px; width: 250px; height: 190px; border-radius: 999px; background: rgba(255,255,255,0.48); filter: blur(14px); pointer-events: none;\"><\/div>\n<div style=\"position: relative;\">\n<h3 style=\"margin: 0 0 14px 0; font-size: 22px; font-weight: 600; color: #111827; border-bottom: 1px solid rgba(17,24,39,0.10); padding-bottom: 8px;\">Key Specifications<\/h3>\n<table style=\"width: 100%; border-collapse: collapse; margin: 0; color: rgba(17,24,39,0.82);\">\n<tbody>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500; width: 38%;\">Model No.<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">ASKA-LTAC-*<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Cable Type<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">Stranded Loose Tube Armored Fiber Optic Cable<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Fiber Count<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">2\u2013216 Cores<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Fiber Type Options<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">G.652 \/ G.655 \/ 50\/125 \/ 62.5\/125<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Sheath Options<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">PE or Anti-Tracking AT Material<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Central Strength Member<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">FRP or Steel Wire<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Armoring Layer<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">APL \/ PSP<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Water Blocking<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">Cable Filling Compound + Water-Blocking Tape<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Max Working Tension<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">1000N \/ 3000N<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Crush Resistance<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">1000N\/100mm \/ 3000N\/100mm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08); font-weight: 500;\">Bend Radius<\/td>\n<td style=\"padding: 10px 12px; border-bottom: 1px solid rgba(17,24,39,0.08);\">Static 12.5D \/ Dynamic 25D<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px 12px; font-weight: 500;\">Operating Temperature<\/td>\n<td style=\"padding: 10px 12px;\">-40\u00b0C to +70\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div style=\"position: relative; overflow: hidden; background: rgba(255,255,255,0.58); border: 1px solid rgba(255,255,255,0.72); border-radius: 28px; padding: 24px 26px; box-shadow: 0 18px 45px rgba(15,23,42,0.10), inset 1px 1px 0 rgba(255,255,255,0.92), inset -1px -1px 0 rgba(15,23,42,0.06); backdrop-filter: blur(26px) saturate(170%); -webkit-backdrop-filter: blur(26px) saturate(170%);\">\n<div style=\"position: absolute; inset: 0; pointer-events: none; background: linear-gradient(145deg, rgba(255,255,255,0.72) 0%, rgba(255,255,255,0.22) 38%, rgba(229,231,235,0.18) 100%);\"><\/div>\n<div style=\"position: absolute; top: -80px; left: -90px; width: 250px; height: 190px; border-radius: 999px; background: rgba(255,255,255,0.48); filter: blur(14px); pointer-events: none;\"><\/div>\n<div style=\"position: relative;\">\n<h3 style=\"margin: 0 0 14px 0; font-size: 22px; font-weight: 600; color: #111827; border-bottom: 1px solid rgba(17,24,39,0.10); padding-bottom: 8px;\">Cable Structure<\/h3>\n<p style=\"margin: 0 0 10px 0; font-weight: 500; color: rgba(17,24,39,0.86);\">Cable Structure Includes:<\/p>\n<ul style=\"margin: 0; padding-left: 20px; color: rgba(17,24,39,0.82);\">\n<li>PE or anti-tracking outer sheath<\/li>\n<li>PE inner sheath<\/li>\n<li>Colored fibers in PBT loose tubes<\/li>\n<li>Tube filling compound<\/li>\n<li>Cable filling compound<\/li>\n<li>FRP or steel wire central strength member<\/li>\n<li>Water-blocking tape<\/li>\n<li>APL aluminum plastic laminate<\/li>\n<li>PSP double-coated plastic-coated steel tape<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Description ASKA-LTAC-* Stranded Loose Tube Armored Cable is designed for outdoor duct and underground fiber optic network installation where added moisture protection and mechanical strength are required. The cable uses colored fibers in PBT loose tubes, an FRP or steel wire central strength member, cable filling compound, water-blocking tape, APL\/PSP armored protection, and PE or [&hellip;]<\/p>\n","protected":false},"featured_media":2871,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[164],"product_cat":[204],"product_tag":[],"class_list":["post-2366","product","type-product","status-publish","has-post-thumbnail","product_brand-askacom","product_cat-duct-cables","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/product\/2366","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/comments?post=2366"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/media\/2871"}],"wp:attachment":[{"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/media?parent=2366"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/product_brand?post=2366"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/product_cat?post=2366"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/askacom.com\/es\/wp-json\/wp\/v2\/product_tag?post=2366"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}